Thermik Product : 1.6A To 7.5A : SW1


Automatic resetting, without base insulation for high performance with connection leads

Contact type
Normally closed
Nominal switching temperature (NST) in steps of 5℃
70℃-160℃
Standard tolerance
±5K
Reset temperature range blow NST (UL/CSA)
depends on NST
Operating voltage...AC/DC - available, values on inquiry
100V up to 250V~
Rated voltage UAC
250V
Rated current
AC cos ϕ = 1.0 (ohmic load) / switching cycles
9A/1,000
Rated current
AC cos ϕ = 0.6 acc. to IEC 60730-2-9
1.6A/1,000
Contact bounce time
< 1 ms
Contact resistance (acc. to MIL-Std. R 5757)
< 50 mΩ
Vibration proof at 10 … 60 Hz 100 m/s²
High voltage insulation (not C - versions) 2 kV
Suitable for protection class I or II
suitable
Standard wiring connection
single wire Ø 0.5 mm / AWG 22
Approvals available (according to design) **
IEC;VDE