Thermik Product : 1.6A To 7.5A : S02


Automatic resetting, without base insulation for high performance with connection leads

Contact type
Normally closed
Nominal switching temperature (NST) in steps of 5℃
60℃-250℃
Standard tolerance
±5K
Reset temperature range blow NST (UL/CSA)
-35K±15K
Operating voltage...AC/DC - available, values on inquiry
up to 500V~
Rated voltage UAC
250V (VDE) 277V (UL)
Rated current
AC cos ϕ = 1.0 (ohmic load) / switching cycles
2.5A/10,000
6.3A/3,000
7.5A/300
Rated current
AC cos ϕ = 0.6 acc. to IEC 60730-2-9
1.6A/10,000
Rated current
AC cos ϕ = 0.4 - 0.5 acc. to IEC 60730-2-3
1.8A/10,000
Max. switching current at
250V ~ / cos ϕ = 0.4 - 0.5 / sw. cycles
7.2A/1,000
Contact bounce time
< 1 ms
Contact resistance (acc. to MIL-Std. R 5757)
< 50 mΩ
Impregnation resistance with- or without resin
(acc. to requirements)*
suitable
Vibration proof at 10 … 60 Hz 100 m/s²
Pressure stability of housing 450N
High voltage insulation (not C - versions) 2 kV
Suitable for protection class I or II
suitable
Standard wiring connection
lead wire 0.25mm² / AVG22
Approvals available (according to design) **
IEC;ENEC;VDE;UL;CSA;CQC;CMJ